English 6
Figure 2: Clearance Requirements with OTR Microwave
5
" (127 mm) min.
to combustible
sidewalls
5
" (127 mm) min.
to combustible
sidewalls
5
" (127 mm) min.
to combustible
sidewalls
18
" (457 mm)
minimum
18
" (457 mm)
minimum
18
" (457 mm)
minimum
Refer to OTR
manufacturers
installation manual
for clearances.
Refer to
OT
R
manufacturer’s
installation manual
for clearances.
Refer to OTR
manufacturers
installation manual
for clearances.
0" Sides
0"
Side
s
0" Sides
0" Bottom
0"
Bottom
0" Bottom
30" (762 mm)
30" (762 mm)
30" (762 mm)
13" max.
cabinet
depth
13" max.
cabinet
depth
13" max.
cabinet
depth
m CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface
m CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface
m CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface
Cabinet Clearances with OTR Microwave
as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
0" Clearance
to back wall
0"
Clearance
to back wall
0" Clearance
to back wall