Loading ...
Loading ...
Loading ...
English 2
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Data Rating Plate
The data rating plate showing the model and serial
numbers of your rangetop is located on the underside of
the rangetop chassis near the front of the unit (Figure 14 on
page 13). This information is required if customer service is
requested. Before installation,
the model and serial
numbers should be entered in the appropriate spaces in
the “BEFORE CALLING FOR SERVICE” section near the
back of the Use and Care Guide. After installation,
accessing the information is difficult.
Electrical Power Supply
Gas Supply
All models are convertible to LP/Propane gas using an
accessory conversion kit (PALPKITHP).
Safety Codes and Standards
This appliance complies with one or more of the following
Standards:
UL 858, The Standard for the Safety of Household
Electric Ranges
ANSI Z21.1, The American National Standard for
Household Cooking Gas Appliances
CAN 1-1.1-M81, Domestic Gas Ranges
CSA C22.2 No. 61, Household Cooking Ranges
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
IMPORTANT:
When installing against a combustible surface, a Low
Backguard is optional. A THERMADOR
TM
Low Backguard
must be purchased separately. See Step 7 for backguard,
kits and installation information.
Rear clearance to a combustible surface is zero inches
(see “Installation Clearances”).
It is
strongly recommended that this appliance be installed
in conjunction with a suitable overhead vent hood (see
“Step 1: Ventilation Requirements” on page 3). Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.
Check local building codes for the proper method of
appliance installation. Local codes vary. Installation,
electrical connections and grounding must comply with all
applicable codes. In the absence of local codes the
appliance should be installed in accordance with the
National Electric Code ANSI Z223.1 current issue and
National Gas Code ANSI/NFPA 70 – current issue. In
Canada, installation must be in accordance with the CAN
1-B149.1 and .2 – Installation Codes for Gas Burning
Appliances and/or local codes.
Voltage
Dedicated
Circuit Rating
Frequency Phase
120 VAC 10 Amps 60 Hz. Single
Gas Type Min. water column Max. water column
Natural 6'' (14.9 mb) 14'' (34.9 mb)
Propane 11'' (27.4 mb) 14'' (34.9 mb)
CAUTION
This unit is designed as a cooking appliance. Based on
safety considerations, never use it for warming or
heating a room.
CAUTION
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the rangetop. The maximum gas pressure
to this appliance must not exceed 14.0'' water column
(34.9 mb) from the propane gas tank to the pressure
regulator.
CAUTION
To eliminate risk of burns or fire caused by reaching over
heated surface units, cabinet storage located above the
surface units should be avoided.
Loading ...
Loading ...
Loading ...