CLEARANCE INSTALLATION DIAGRAMS
B
C
C
A
B
2) Parallel Installation, Single Wall Pipe, Back Vent
NO HEAT SHIELD
A. Back of stove to wall = 23” D. Side of stove to wall = 19”
B. Back of pipe to wall = 15” E. Side of pipe to wall = 29.5”
C. Above pipe to ceiling = 18”
WITH REAR SHIELD & PIPE SHIELD ATTACHED
A. Back of stove shield to wall = 14” D. Side of stove to wall = 19”
B. Back of pipe shield to wall = 6” E. Side of pipe to wall = 29.5”
C. Above pipe to ceiling = 18”
WITH REAR HEAT SHIELD & PIPE SHIELD ATTACHED
A. Back of stove shield to wall = 6” D. Side of stove to wall = 19”
B. Back of pipe shield to wall = 6” E. Side of pipe to wall = 29.5”
C. Above pipe to ceiling = 18”
D
9
NO HEAT SHIELD
A. Back of stove to wall = 14” D. Side of stove to wall = 19”
B. Back of pipe to wall = 15” E. Side of pipe to wall = 29.5”
C. Above pipe to ceiling = 18”
1) Parallel Installation, Single Wall Pipe, Top Vent
A
E
E
D