For KSSC42QKS00. Also, The document are for others KitchenAid models: KSSC36FKB00, KSSC36FKS00, KSSC36QKS00, KSSC42FKB00, KSSC42FKS00, KSSC48FKB00, KSSC48FKS00, KSSC48QKS00, KSSP36QKS00, KSSP42QKS00, KSSP48QKS00, KSSS36FKB00, KSSS36FKT00, KSSS36FKW00, KSSS36FKX00, KSSS36QKB00, KSSS36QKT00, KSSS36QKW00, KSSS36QKX00, KSSS42FKB00, KSSS42FKT00, KSSS42FKW00, KSSS42FKX00, KSSS42QKB00, KSSS42QKT00, KSSS42QKW00, KSSS42QKX00, KSSS48FKB00, KSSS48FKT00, KSSS48FKW00, KSSS48FKX00, KSSS48QKB00, KSSS48QKT00, KSSS48QKW00, KSSS48QKX00

PDF File Manual, 76 pages, Read Online | Download pdf file

KSSC42QKS00 photo
Loading ...
Loading ...
Loading ...
6-1
DIAGNOSIS & TROUBLESHOOTING
DIAGNOSIS
PRE-DIAGNOSTICS CHECKS
Confirm the refrigerator and freezer tem-
peratures before beginning other checks.
See if the compressor, evaporator, and
condenser fans are running.
Check the position of the air door.
DIAGNOSTICS MODE
The Diagnostics Mode is used to:
Check the refrigerator & freezer ther-
mistors.
Operate the evaporator fan motor at 3000
rpm.
Operate the condenser fan motor and com-
pressor.
Check the defrost bimetal and heater.
To enter the Diagnostics Mode, the control
must be turned on, and be in a normal cooling
mode.
Power
On/Off
Warmer
Colder
Warmer
Colder
FREEZER REFRIGERATOR
WATER FILTER
PERCENT LEFT
RESET
°C
SELECT
Both the Power On/Off and the Water Filter
Reset keys must be functional. The refrigera-
tor display shows the step number. The results
of the checks are displayed on the water filter
status indicator. After 20 minutes, the control
will default from the Diagnostics Mode to a
normal cooling mode.
To enter the diagnostics mode:
Press and hold the Water Filter Reset
keypad, and then immediately press and
hold the Power keypad. Continue to press
both keypads for 3 seconds, or until you
hear a beep.
To advance the diagnostics sequence:
To advance to the next step in the se-
quence, press and hold the Water Filter
Reset key for 2 seconds, or until you hear
a beep. The Diagnostics Chart on the next
page shows the step number and the com-
ponent being tested in each step.
Downloaded from www.ManualsFile.com manuals search engine