Pre-Installation (continued)
FOLLOW THESE GUIDELINES WHEN INSTALLING DUCT WORK:
- Your venting system must vent to the outdoors either horizontally through the back wall (13) or vertically through
the roof (14) (refer to Fig. 5/Fig. 6/Fig. 7).
- Use round metal duct work with a uniform diameter of 177 mm (7 in). The total duct run in the venting system
should not be more than 10.7 m (35 ft).
- Calculate the total effective length of the duct work by adding the equivalent lengths in the table shown (Fig. 9).
For each tting used add the length of the equivalent straight duct used in the system.
- Fasten all connections between pieces of duct with sheet metal screws and tape all joints with certied duct tape.
- If you must turn the path of the duct work using elbows, keep the number of elbows to a minimum for effective
performance and use no more than three 90° elbows. Ensure that there is a minimum of 458 mm (18 in) of
straight vent between each elbow. Elbow as far away from the range hood’s exhaust opening as possible.
- Cap the exterior of the duct with a wall cap (15) or roof cap (16). Never use 102 mm (4 in) laundry-type wall caps.
Use caulking to seal exterior wall or roof opening around the cap.
- The venting system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied
with the range hood.
13
15
Horizontal Wall Venting
Fig.5
Vertical Roof Venting
14
16
Fig.7
13
Horizontal Wall Venting
Fig.6
15
For inside venting system (air does not exhaust to outdoors) (Fig. 8):
Please refer to the Installation section. The cover on the top plate will be removed and air will be exhausted through the
charcoal lter and out from 17.
17
Fig. 8
Equivalent Length Chart
Type of duct Length added
45
° Elbow 0.91 m (3 ft)
90° Elbow 1.52 m (5 ft)
90° Flat elbow 3.66 m (12 ft)
2.74 m (9 ft) Straight duct 2.74 m (9 ft)
Wall cap 0 m (0 ft)
Fig. 9