general information
!
WARNING
Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
This appliance must be installed by a qualifi ed installer. Follow the installation directions. Do not operate
without fully assembling all components.
If this appliance is not properly installed, a house fi re may result.
Do not expose the appliance to the elements (ex. rain, etc.) and keep the appliance dry at all times. Wet
insulation will produce an odour when the appliance is used.
This appliance is hot when operated and can cause severe burns if contacted. Children and pets must be
kept from touching the appliance when it is hot. Contact your local authorized dealer/distributor for safety
screens that may be available for this product.
Combustible material such as fi rewood, wet clothing, etc. placed too close can catch fi re. Objects placed
in front of the appliance must be kept a minimum of 48” (121.9cm) from the front of the appliance.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with
the National Electric Code ANSI/NFPA NO. 70-Current (in the United States), or with the current CSA
C22.1 Canadian Electric Code (in Canada).
This appliance and its components are designed to be installed and operated as a system. Any alteration
to or substitution for items in this system, unless allowed by these installation instructions, will void the
OMNI listing and may void the product warranty. It may also create a hazardous installation. Read through
these instructions thoroughly before starting your installation and follow them carefully throughout your
project.
2.1 general instructions
1. Combustion air is brought into the appliance
through the slots and around the glass door
or through the screen.
2. Outside air is controlled with a damper to
supplement indoor air. The damper can only
be adjusted to be fully closed or fully open.
3. Inside the fi rebox, combustion takes place
and exhausts out the chimney.
4. The appliance includes a fl ue damper at the
base of the chimney which shall be closed
when the appliance is not in use to prevent
cold air entering the home. See "fi rebrick
installation and damper operation" section.
2
3
3
1
4
OPEN
CLOSED
OPEN
The location of windows and doors, as well as the traffi c fl ow in the room where the appliance is to be located should
be considered. If possible, choose a location where the chimney will pass through the house without cutting a fl oor or
roof joist.
It is recommended to test the listed
components below before installation:
• Doors
• Balance weights
Louvre for air intake
• Flue damper
All components should be in good operating
condition before the appliance is installed.
note: