framing
5.4 minimum mantel clearances
An optional combustible mantel must be a minimum of 12" (30.5cm) above the top of the faceplate and not to
extend more than 2" (51mm) from the surface. See chart below for further information.
TOP OF
FACEPLATE
(KEYSTONE)
EFGH
A
B
C
D
A = 8" (203mm)
B= 6" (152mm)
C= 4" (102mm)
D= 2" (51mm)
E = 12" (30.5cm)
F= 14" (35.6cm)
G= 16" (40.6cm)
H= 18" (45.7cm)
I
I = NZ7000 31 1/8" (79.1cm)
I = NZ8000 40 1/4" (102.2cm)
!
WARNING
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions
may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.