Installation and User Instructions R02889-3 04/14
Page 23
Commissioning
the electronic components on the
cylinder.
6.2.6 Set Tariff
- enter the service menu.
- rotate the dial to select tariff and
press the dial to select
- the tariff can be set to either Off-
peak or Timed.
- Off peak tariff heats the cylinder
using the bottom immersion heater
to the primary setpoint whenever
an off peak power supply is
available
- Timed tariff requires that time
period is set during which the
cylinder will be heated to the
primary temperature setpoint
6.3 Confirmation of
Operation
Operation of the cylinder shall be
confirmed as follows:
a) with a cold tank, use a current
tester; or
b) verify that the outlet pipe feels
warm within 1 h of startup.
Note: This should only be attempted
if the insulation may be disturbed
slightly without damage.