Checklist Before Installation
Refer to this checklist before installation.
Water QualityIf the water supply contains sand, sulfur, bacteria, iron bacteria, tannins, algae, oil, acid, or other unusual
substances, pre-treat the water to remove these contaminants before the water supply enters the appliance, unless the
appliance is represented as being capable of treating these contaminants in its specifications.
The appropriate WaterBoss
®
Water Filter can address these water shortcomings.
Model 900-IF (Iron Filter)Reduces iron, manganese, hydrogen sulfide, and iron bacteria.
Model 900-NF (Acid Neutralizing filter)Adjusts low pH water to a non-corrosive state.
IronA common problem found in many water supplies is iron. It is important to know what type of and how much iron is
in the water supply.
Iron Type
Description
Ferrous Iron* (sometimes called
clear water or dissolved iron)
Only type of iron that can be treated with a water softener
Ferric Iron
Insoluble and the particles can eventually foul a resin bed. It should be filtered out before the
water reaches the softener
Organic Iron or Bacterial Iron
Attached to other organic compounds in the water. Additional treatment is needed to remove
this type of iron
Colloidal Iron
Not dissolved, yet stays in suspension. A softener cannot remove this type of iron
* If the water supply contains ferrous iron, a commercially available resin bed cleaner should be used every six months. Follow the
instructions on the container. You should also increase your water hardness setting by 5 grains per gallon (8.6 mg/L x 10) for every
1 ppm (1 mg/L) of ferrous iron.
Water Characteristics—Softeners require a pH of 7 or above to function properly. An iron test to determine iron levels is
also necessary. The 900-NF Acid Neutralizing Filter adjusts pH levels of 6.3 or above.
Water HardnessDouble check hardness of water with test strips provided to verify that your appliance is right for
the job.
Model Pro180 will condition water for up to 70 grains of hardness per gallon (1200 mg/L).
Model ProPlus380 will condition water for up to 100 grains of hardness per gallon (1710 mg/L). (See Specifications.)
Water PressureNot less than 20 psi (1.4 bar) or greater than 120 psi (8.3 bar) constant. If water pressure exceeds
70 psi (4.8 bar), a pressure regulator is recommended.
Water Supply Flow RateA minimum of 3.0 gallons (11.4 L) per minute is recommended. For the purposes of plumbing
sizing, only the rated service flow rate and corresponding pressure loss may be used. Prolonged operation of a water
conditioner at flow rates exceeding the tested service flow rate may compromise performance.
Water TemperatureNot less than 40°F (4°C) or greater than 120°F (49°C).
DrainDrain the appliance to an appropriate drain, such as a floor drain or washer drain that will comply with all local
and state plumbing codes. To prevent back-siphoning, provide an adequate air gap or a siphon break. See Installation
Steps and Start-Up Procedures.
ElectricityThe transformer supplied is for a standard 115 volt, 60-cycle AC outlet for locations in North America or
220 volt, 50-cycle AC outlet for locations outside North America.
If you have any questions, call the HelpLine. See General Information at the front of the manual for information about the
HelpLine.
These claims have not been tested by NSF.
Loading ...
Loading ...
Loading ...