39
Technical Data
8.1 Cylinder heat exchanger pressure drop
Figure 13: Heat exchanger pressure drops for 2.2m² and 2.8m² coils
0
2000
4000
6000
8000
10000
12000
14000
0.0 0.5 1.0 1.5 2.0 2.5
Pressure Drop (Pa)
Flow Rate (m
3
/h)
2.2 m
2
Coil Pressure Drop
0
2000
4000
6000
8000
10000
12000
14000
0.0 0.5 1.0 1.5 2.0 2.5
Pressure Drop (Pa)
Flow Rate (m
3
/h)
2.8 m
2
Coil Pressure Drop