Loading ...
Loading ...
Loading ...
6
www.napoleongrills.com
N415-0272-AU JAN 24.18
CYLINDER SIZE OPENING A AREA OPENING B AREA
9.1 kg
200 cm
2
200 cm
2
127 mm
MAXIMUM
25.4 mm
MAXIMUM
OPENING
A
OPENING
B
51 mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
864 mm
RECOMMENDED
BUILT IN UNIVERSAL LIQUEFIED PETROLEUM GAS HOOK-UP: The piping up to the gas grill is the
responsibility of the installer and piping should be located as shown in the built-in instrucons. A exible
metal connector is included to simplify the installaon of the unit. Connect this exible metal connector
to the are ng with 3/8” SAE 45
O
Flare Inlet Connecon (5/8-18 UNF thread) on the end of the
manifold. Connect the other end of the connector to the supplied bole regulator. Ensure that the exible
metal connector is protected from damage if it needs to pass through any parons. The installaon must
be performed by a licensed gas er in accordance with AS/NZS 5601, and all connecons must be leak
tested before operang the grill.
If the enclosure is to house a ULPG cylinder, the tank poron of the enclosure must be venlated accord-
ing to the BUILT IN CYLINDER ENCLOSURE instrucons, and must not have communicaon with the cavity
used to enclose the gas grill. A ULPG cylinder cannot be stored below the gas grill or side burner.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 200 cm
2
for a 9.1 kg cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 25 mm or less
from the oor level. The opening must have a total free area of more than 200 cm
2
for a 9.1 kg cylinder.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
WARNING!
• The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the
use of tools.
• The enclosure for the ULPG-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
• The enclosure must be designed so that the ULPG-gas cylinder can be connected, disconnected and
the connecons inspected and tested outside the cylinder enclosure. Any connecons that can
be disturbed when installing the cylinder in the enclosure must be accessible for tesng inside the
enclosure.
Loading ...
Loading ...
Loading ...