N415-0272-AU JAN 24.18
CYLINDER SIZE OPENING A AREA OPENING B AREA
9.1 kg
200 cm
2
200 cm
2
127 mm
MAXIMUM
25.4 mm
MAXIMUM
OPENING
A
OPENING
B
51 mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
864 mm
RECOMMENDED
BUILT IN UNIVERSAL LIQUEFIED PETROLEUM GAS HOOK-UP: The piping up to the gas grill is the
responsibility of the installer and piping should be located as shown in the built-in instrucons. A exible
metal connector is included to simplify the installaon of the unit. Connect this exible metal connector
to the are ng with 3/8” SAE 45
O
Flare Inlet Connecon (5/8-18 UNF thread) on the end of the
manifold. Connect the other end of the connector to the supplied bole regulator. Ensure that the exible
metal connector is protected from damage if it needs to pass through any parons. The installaon must
be performed by a licensed gas er in accordance with AS/NZS 5601, and all connecons must be leak
tested before operang the grill.
If the enclosure is to house a ULPG cylinder, the tank poron of the enclosure must be venlated accord-
ing to the BUILT IN CYLINDER ENCLOSURE instrucons, and must not have communicaon with the cavity
used to enclose the gas grill. A ULPG cylinder cannot be stored below the gas grill or side burner.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 200 cm
2
for a 9.1 kg cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 25 mm or less
from the oor level. The opening must have a total free area of more than 200 cm
2
for a 9.1 kg cylinder.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the
use of tools.
The enclosure for the ULPG-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
The enclosure must be designed so that the ULPG-gas cylinder can be connected, disconnected and
the connecons inspected and tested outside the cylinder enclosure. Any connecons that can
be disturbed when installing the cylinder in the enclosure must be accessible for tesng inside the
enclosure.