Subsequently, using a 7 mm hexagonal wrench, loosen the injector I (fig. n° 13A) and
replace it following the indications in the table “Oven gas burners technical data”
Injector (page 15). Re-mount the burner following the above described operations, but in
reverse order, and following the instructions for adjustment of the by-pass.
Save the orifices removed from the appliance for future use.
2) Adjustment by-pass
Remove the thermostat knob. Using a small flat tip screwdriver, find the by-pass screws
(figures 11 and 11A). Turn right until the screw is completely closed. Then turn the by-
pass screw left by the number of degrees indicated in the Technical Data chart “Value
by-pass” (page 15).
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to match the type gas supply used. If
converting from natural gas to LP gas, the appliance pressure regulator must be converted
to regulate LP gas. If converting from LP gas to natural gas, the appliance pressure
regulator must be converted to regulate natural gas. To install the gas regulator you must
use a CSA-certified Pipe Sealant only.
To convert the appliance pressure regulator from one gas to another; remove the cap,
push down and turn counter-clockwise. Turn the cap over and reinstall, follow the NAT or
LP indication (figure 12).
Inlet Pressure in Inches of Water Column
PRESSURE
Minimum Maximum
Natural gas
4
7
LP gas
11
14
NOTE: THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE ON THE TOP
OF THE INSTALLED APPLIANCE PRESSURE REGULATOR CAP.
SERVICE PARTS INFORMATION
When your range requires service or replacement parts, contact your dealer or authorized
service agency. Give the complete model and serial number of the range which is located
on the range model number plate.
LOW SETTING VALVE ADJUSTMENT
The LOW setting should produce a stable flame when turning the knob from HIGH to
LOW. The flame should be 1/8 inch or lower and must be stable on all ports on LOW
setting.
To adjust: Operate burner on HIGH for about five minutes to preheat burner itself. Turn
knob back to LOW; remove knob, and insert a small flat tip screwdriver on left side slot
(figs. 11 and 11A). Adjust the flame size by turning adjustment screw in either direction.
Flame must be of sufficient size to be stable on all burner ports. If flame adjustment is
needed, adjust ONLY on the LOW setting. Never adjust flame size on higher setting.