Installation Instructions (Continued)
MINIMUM FLOW ADJUSTMENT FOR COOKTOP GAS TAPS
IMPORTANT! All work must be carried out by a registered gas tter and in accordance with the current
standards.
WARNING! Always isolate the cooktop from the electricity and gas supply before changing the
injectors and/or adjusting the minimum ow of the burners.
Switch the burner on and set the knob at the minimum position.
Remove the knob from the tap and place a small bladed screwdriver in the centre of the
tap shaft.
Unscrew the adjusting screw, in order to increase the gas ow or tighten the adjusting
screw to decrease the gas ow.
The correct adjustment is obtained when the ame has a length of about 3 4 mm.
For ULP gas, the adjusting screw must be tightly screwed in.
Ret the control knob.
Make sure that the ame does not go out by quickly turning from maximum ow to
minimum ow. If it does then remove the control knob and make further adjustments to
the gas ow, testing it again once the adjustment has been made.
Repeat this process for each one of the gas taps.
When converting from Natural Gas to ULP gas ensure that the NG regulator is removed
and replaced with the Test Point Assembly. A gas regulator suitable for a supply pressure
of 2.75kPa should be at the inlet to the appliance. Replace the old data plate with one
which is suitable for the type of gas for which the appliance has been regulated.
IMPORTANT! Where this appliance is installed in marine craft or in caravans, it shall not be used as a
space heater.