Installation Instructions (Continued)
GAS CONNECTION
Install in accordance with relevant gas standards and/or codes of practice applicable.
Connect the elbow tting to the appliance gas manifold connection, and check that seals between the elbow and
manifold connection are in place and in good condition.
For Natural gas: connect the natural gas appliance regulator (pictured below) with
integral test point using approved gas thread tape or compound to the elbow tting.
For Universal LPG: connect the brass test point adaptor (pictured below) using approved
gas thread tape or compound to the elbow tting.
Ensure the supply connection point, test point and natural gas regulator adjustment screw (for Natural gas installation)
are accessible for testing and/or adjustment with the hotplate in the installed position.
Where a exible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B or D and the maximum length is
1.5m. Any hose assembly used must be restrained from accidental contact with the ue outlet of an under bench oven.
This hose assembly shall be suitable for connection to a xed consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the oor and in the region outside the
width of the appliance to a distance of 250 mm.
After connecting to gas, check for leaks using soapy solution, never a naked ame.
Gas pressure may be checked by test point located on regulator or LPG test point
adaptor. Adjust regulator to the required pressure as shown on data plate, check burner
ignition & and the ame is burning correctly.
If, after installation and checking the appliance operation, the hotplate is not working
correctly, contact the Residentia Support team on 1300 11 4357 for assistance.
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the
hotplate, for example, the inside of the cupboard door so it is clearly visible for any
service technician.