802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015- V2.00 Page 3 of 24
Tap Safety - Boiling Models
B
Boiling Models (Classic, Elite & AIO)
To set the safety using the touch screen:
1.
Press the [MENU] button for
main menu.
2.
Press the [Setting] button.
3.
Press the [Safety] button.
4. Press button to Enable /
Disable, the safety lock feature
on the tap.
B
On Boiling Only models the safety lock feature is provided to prevent boiling
water flowing if any of the Classic hot levers or Elite buttons are inadvertently
operated.
The Safety Lock button on the tap can only be Disabled or Enabled from the
LCD touch screen (Located on the unit in the cupboard). When Disabled, no
water will be dispensed from the Boiling Hydrotap.
For HydroTap ARC/CUBE:
(Boiling Ambient and Boiling models)
The safety on the tap, can only be Disabled or Enabled from the LCD touch
screen (Located on the unit in the cupboard).
Light intensity varies from site to site, therefore it is recommended that a
re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap, during the
calibration. This can be achieved by closing any nearby curtains, blinds, etc.
or by shading the tap with a dark cloth.
Safety Sensor Calibration (lever models)
Pull both levers forward
Safety
sensor
1.
With the unit in Normal operating mode
and with the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward
position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral
position.
7.
To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.