Page 18 of 24 802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00
To edit the filter usage:
This function is to reset the Filter
Change display after a filter has reached
the end of its life (refer to “Replace
Filter Instructions” section of this
document).
1.
Press the [MENU] button for main
menu.
2.
Press the [Setting] button.
3.
Press the [Filter] button.
4.
Press the [Edit Filter] button for
Internal or External filter.
5.
To edit, select Edit Usage(Litres) or
Edit Usage (Months), then adjust
using the up or down arrows.
3. LCD Screen operation - Section G
This mode allows the HydroTap to Go into Energy Saving mode. There are
two options available: ‘Sleep’ mode and ‘ON/OFF’ mode.
To activate the sleep mode:
1. Press [MENU] button for main
menu.
2. Press [Setting] button.
3. Press [Energy Modes] button.
4. Press [Sleep Modes] button then in
the next screen, use the up and down
arrows to select one of the 7 options, as
shown in the table below.
Energy Modes
In Sleep Mode the unit will Go to “Sleep” after a 2hr period of inactivity.
The Boiling water will gradually drop to either 68°C or room temp, as shown
in the table below and the Chilled water will be ON or OFF.
When the period of inactivity passes, the home screen status window will
show “Sleep Mode”.
Sleep Mode
Light
Level
Time
Delay
State Boiler Chiller
2 Hours-> 68°C N/A 2 Hr Sleep 68°C ON
2 Hours-> OFF N/A 2 Hr OFF OFF OFF
Lux Sensor->68°C Dark N/A Sleep 68°C ON
Lux Sensor-> OFF Dark N/A OFF OFF OFF
Lux or 2 Hr-> 68°C Dark 2 Hr Sleep 68°C ON
Lux or 2 Hr-> OFF Dark 2 Hr OFF OFF OFF
Disable N/A N/A ON ON ON
Loading ...
Loading ...
Loading ...