Page 14 of 24 802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00
After replacing the filter, the counters should be reset
1. Press the [MENU] button for main
menu.
2. Press the [Install] button.
3. Press the [Hot Calibration] button.
4. In the next screen, press [Calibrate] if
you want to start calibration.
Boiling Calibration Screen
3. - Boiling Calibration
1. Press the [MENU] button for main
menu.
2. Press the [Install] button.
3. Press the [Booster] button.
4. If a Booster is installed, select YES to
enable the Booster.
5. Dispense boiling water for 30 secs
and check the outlet hose from the
Booster is warm.
6. Otherwise select NO, if no Booster is
installed
This function should only be considered when a Booster unit is installed.
G4 HydroTap Booster Screen
4. - Booster
Note:
Failing to make the correct selection for ‘Booster’ will effect product
performance.
2. - Filter Reset
LCD Screen operation - Section C
1.
Press the [MENU] button for main
menu.
2.
Press the [Install] button.
3.
Press the [Filter Reset] button.
4.
To set the filter life or edit filter
usage, refer to section G- Filter.
On start up, the Zip HydroTap starts a self-calibration program. The controls
take the system through the calibration process. Once complete, the system
reverts back to normal operation. If you would like to calibrate the system
anytime after initial installation, please follow the steps below.
Caution:
During calibration, boiling water units may vent steam from the
tap spout. Take care to avoid personal injury whenever this occurs.