Loading ...
Loading ...
Loading ...
32
/3&RQYHUVLRQ,QVWUXFWLRQV
&219(57685)$&(%851(56
A
Remove all grates and burner modules.
B
With an adjustable wrench or an open end wrench,
remove the brass orifices.
C
Find the inscribed LP orifices in the holder in the front
of the electric cover beneath the cooktop.
D
Install the inscribed LP orifices in place of the natural
gas orifices.
E
Replace the burner modules and grates.
)
Keep all the spuds with your cooktop so you have
them if you move or get a different gas hook-up.
2
/33URSDQH*DVµ:&3
%XUQHU2XWSXW5DWLQJLQ%78+5
/RFDWLRQ %78V 2ULILFH6L]H (QJUDYLQJ
Left Rear (LR) 9,100 .0354 LP
Left Front (LF) 9,100 .0354 LP
Right Rear (RR) 9,100 .0354 LP
Right Front (RF) 9,100 .0354 LP
Turn counterclockwise to remove
Orifice
Turn clockwise to tighten
$'-867*5,//%851(5$,56+877(5
The air shutters for the grill burner may need to be
adjusted to get better flame appearance and ignition.
The air shutters for the grill burner are located on the
bottom of the grill burner. To access the air shutters,
remove the grill grate, and then the grill burner. Loosen
the screw and slide the air shutter backward or forward
to increase or decrease the size of the air opening.
Re-tighten the screw.
3
Air shutter
Loosen screw
Adjust air shutter opening
Tighten screw
&+(&.,*1,7,21
Connect electrical supply cord.
B
Turn on the gas; check for leaks using a liquid leak
detector at all joints in the system.
:$51,1*'212786($)/$0(72
&+(&.)25*$6/($.6
Push in one control knob and turn
to the /,7( position. The igniter will
spark and the burner will light. The
first test may require some time
while air is flushed out of the gas
line. After ignition, turn the control
knob to the+, position and wait
until the flame settles.
C
Check to determine if your burner flames are normal.
If burner flames look like A, turn off the burner and
make sure all parts are assembled correctly.
Reassemble and check.
Normal burner flames should look like B or C,
depending on the type of gas you use. With LP gas,
some yellow tipping on outer cones is normal.
D
Turn the knob to 2)).
E
Repeat the procedure for each burner.
4
$²<HOORZIODPHV
Not normal;
check
alignments
%²<HOORZWLSV
Normal for LP
gas
&²6RIWEOXHIODPHV
Normal for
natural gas
A
Loading ...
Loading ...