TECHNICAL DATA
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
Protection against the parts under tension must be ensured after the building-in.
The data of connection necessary are on the stickers place on the cooktop casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz. Always
connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the cooktop casing. To open the cover use
a medium screwdriver. Place it in the slits and open the cover.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz 1 Phase + N 3 x 2.5 mm²
H 05 VV - F H
05 RR - F
25 A *
400V~ 50/60Hz 2 Phases + N 4 x 1.5 mm²
H 05 VV - F H
05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the cooktop
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L to one of the terminals
1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L1 to the terminals 1 and
the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
9
We cannot be held responsible for any incident resulting from incorrect connection or which
could arise from the use of an appliance which has not been earthed or has been equipped
with a faulty earth connection.