Loading ...
Loading ...
Loading ...
6-8
6-8
Electrical servicing
Start the engine the MIL should come on.
If the MIL comes on, replace the ECM with a known
good one and recheck the MIL indication.
If the MIL does not come on, check for open circuit
between green wire terminal of MIL 4P (White) connec-
tor and White/blue wire terminal of the wire harness
side ECM 32P (Black) connector.
If the wire is OK, replace the combination meter.
Tool:
Test probe 07ZAJ-RDJA110
(1) 4P (WHITE) CONNECTOR(1) PROBE
Mil circuit troubleshooting
If the MIL does not come on when the engine start, check
as follows:
Stop the engine
Disconnect the ECM 32P (Black) connector
Ground the White/blue wire terminal of the wire har-
ness side ECM 32P (Black) connector with a jumper
wire
(1) 32P CONNECTOR GENERAL INSTALLATION