FREESTANDING COOKERS
The air adjustment is to be carried out with the flame at the maximum, with a screwdriver loosen screw
“F” and move the cylindrical sleeve “R” towards the injector to decrease the air, move it away from the
injector to increase the air. Once the correct aeration is achieved tighten screw “F” to fix the position.
Examples:
A. Flame with excess of air: it is small, tight and separated. Move forward the cylindrical sleeve R placed
in front of the injector.
B. Flame with lack of air; it is floppy with yellow streaks. Move backward the cylindrical sleeve R placed in
front of the injector.
C. Normal flame: its colour is light blue
AIR ADJUSTMENT
ILVE FREESTANDING COOKERS OPERATING MANUAL