Air and Water Cooled User Manual
November 2012
Page 2
Installation: Product Specications
Location Limitations:
The product is designed to be installed indoors, in a
controlled environment. Air cooled models discharge
very warm air into the room out the back. Space must
be allowed at the left side and back for air intake and
discharge. Water cooled models discharge warm
water into the building’s drain.
Space needs to be provided on both sides and above
for service access.
Space Limitations
Note: Although the machine will function, ice capacity
of air cooled machines will be signicantly reduced
with minimal clearance at the sides, back and
top. Some space is recommended for service and
maintenance purposes on all models. 6" of space
at the sides and back are required for adequate
operation. To get the most capacity, locate the
machine away from heat producing appliances and
heating ducts, and keep the left side away from any
wall, allow 12-18 inches of space at the left for
good air ow.
Airow is in the left side, out the back (as viewed from
the front).
Environmental Limitations
Minimum Maximum
Air temperature 50
o
F. 100
o
F.
Water temperature 40
o
F. 100
o
F.
Water pressure 20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
115 volt model 104 volts 126 volts
230 volt model 198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
Product Information
The product is a modular cuber. That type of machine
is designed to be placed on an ice storage bin or
an ice dispenser. Many installations only require the
matching bin, but some also require an adapter to
be placed between the bin and the cuber or between
the dispenser and the cuber. This product cannot be
stacked. See the chart for application information.