C0322 through C1030
Air and Water Cooled User Manual
November 2012
Page 20
Air cooled condenser lter
1. Pull air lter(s) forward from side panel.
2. Wash the dust and grease off the lter.
3. Return it to its original position.
Do not operate the machine without the lter in place
except during cleaning.
Air cooled condenser
If the machine has been operated without a lter the
air cooled condenser ns will need to be cleaned.
They are located under the fan blades. The services
of a refrigeration technician will be required to clean
the condenser.
Exterior Panels
The front, top and side panels are durable stainless
steel. Fingerprints, dust and grease will require
cleaning with a good quality stainless steel cleaner.
Note: If using a sanitizer or a cleaner that contains
chlorine on the panels, after use be sure to wash the
panels with clean water to remove chlorine residue.
Water lters
If the machine has been connected to water lters,
check the cartridges for the date they were replaced
or for the pressure on the gauge. Change cartridges
if they’ve been installed more than 6 months or if the
pressure drops too much when the ice machine lls
with water.