4
Cabinet Layout
All maximum/minimum dimensions and clearances in the
diagrams below must be maintained for safe operation.
Install the range away from drafts, and include a hood or
approved downdraft.
For safety’s sake, do not install cabinets above the range; other-
wise, install a hood that extends 5” or more past the cabinet face.
The range may be installed against the rear wall. You should
install a backguard or non-combustible material on the wall
between the range and hood. Non-combustible material is not
needed behind the range from countertop to floor.
Seal openings in the wall behind the range or in the floor below.
Planning the Installation
IMPORTANT: Read
ERV3015 Installation
Instructions for duct/
electrical installation
requirements. Use only
the specified Dacor
downdraft model.
A downdraft with a 3-in. backguard requires adding the
ATKERV-RP30 trim kit to create a uniform unit.
Install the ATKERV-RP30 trim piece, which will cover the
downdraft chassis, on the back of the range.
Gas and Electrical Service
The shaded area in the diagram below shows the recommended
location of the gas inlet and the electrical outlet. (If replacing a
range, the existing utilities may be used if they do not interfere
with the placement of this range. Check local codes for
permissible gas-valve locations.)
An external, manual shut-off valve must be installed between
the gas inlet and range so the gas supply can be turned on/off
The installation must also allow:
- access to the gas shut-off valve when the unit is installed.
- access to the electrical outlet, when the range is in place.
- the range to be pulled out for service without disconnecting
the gas and electrical supply.
Cutouts and Tolerances
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Callout Dimension
F Recommended: 36” (91.4 cm); Min.: 30” (76.2 cm)
G Minimum: 30” (76.2 cm)
H 27 1/2” (69.9 cm)
I 3 1/2” (8.9 cm)
APPROVED DOWNDRAFT
Range HGPR30S
Downdraft ERV3015
Trim Kit
ATKERV-RP30 (Needed
if using 3-in backguard)
G
10" (25.4 cm) min.
to combustible side
walls above the range
(on both sides)
non-combustible
rear wall (recommended)
H
Backsplash
3/8" (1.0 cm)
min. for downdraft cap
clearance
J
Note 2
I