WARNING
• Follow all codes and ordinances during planning/installation.
Contact your local building department for details.
• To avoid an electric shock hazard, the power supply must
meet the specifications below. The owner shall ensure the
electrical service meets requirements and that the outlet is
installed by a licensed electrician.
The range must be grounded per local codes, or in their absence,
per the National Electrical Code, ANSI/ NFPA 70.
Electrical Requirements
• The range is comes with a 6-ft. power cord with a 3-prong
grounding plug connected to the rear of the range. It must be
plugged in to a dedicated, grounded 3-prong electrical outlet.
• The range must receive the correct voltage/frequency/amperage
from a separate, grounded circuit protected by a proper-size
circuit breaker or time-delay fuse.
Circuit Required Total Connected Load*
120 Vac, 60 Hz, 15 Amp.
120 Vac 60 Hz, 5.0 Amp.
*These specifications are for reference only. See the rating label (back
of range) for exact spec’s.
Planning the Installation
GAS-/ELECTRICAL-ACCESS DIMENSIONS
A B
13 1/16” – 14 3/8” (33.18 – 36.51 cm) 4 5/16” (10.95 cm)
Power cord
Gas Inlet
Gas and Power Access (panels removed
to show gas connections)
Gas-Supply Requirements
• Installation of this range must comply with local codes or, in their
absence, the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• Ensure the range matches the home gas service (natural gas or
LP gas).
• If using the range above 4000 ft. (1219 m), ensure it is equipped
for high-altitude use. See the rating label (inside cover) to verify
that you have the proper model.
• The gas-supply pressure requirements in this table are for
reference only. (See the rating label for exact specifications).
GAS-SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Minimum Manifold
Pressure
Min. Gas-Supply
Pressure**
Natural Gas 5-in. Water Column 6-in. Water Column
Liquid Propane (LP) 10-in. Water Column 11-in. Water Column
*Gas-supply pressure for testing the regulator setting shall be at least 1 in. water
column (249 Pa) above the specified manifold pressure; **Max. gas-supply pressure
for all models: 1/2 psi.
• The regulator is factory-installed. Use only the installed regulator.
The regulator inlet receives a 3/4” gas line. The range ships with
a 1/2”-to-3/4” adapter on the regulator.