2
WARNING
Follow all codes and ordinances during planning/installation.
Contact your local building department for details.
To avoid an electric shock hazard, the power supply must
meet the specifications below. The owner shall ensure the
electrical service meets requirements and that the outlet is
installed by a licensed electrician.
The range must be grounded per local codes, or in their absence,
per the National Electrical Code, ANSI/ NFPA 70.
Electrical Requirements
The range is comes with a 6-ft. power cord with a 3-prong
grounding plug connected to the rear of the range. It must be
plugged in to a dedicated, grounded 3-prong electrical outlet.
The range must receive the correct voltage/frequency/amperage
from a separate, grounded circuit protected by a proper-size
circuit breaker or time-delay fuse.
Circuit Required Total Connected Load*
120 Vac, 60 Hz, 15 Amp.
120 Vac 60 Hz, 5.0 Amp.
*These specifications are for reference only. See the rating label (back
of range) for exact spec’s.
Planning the Installation
GAS-/ELECTRICAL-ACCESS DIMENSIONS
A B
13 1/16” – 14 3/8” (33.18 – 36.51 cm) 4 5/16” (10.95 cm)
Power cord
Gas Inlet
Gas and Power Access (panels removed
to show gas connections)
Gas-Supply Requirements
Installation of this range must comply with local codes or, in their
absence, the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Ensure the range matches the home gas service (natural gas or
LP gas).
If using the range above 4000 ft. (1219 m), ensure it is equipped
for high-altitude use. See the rating label (inside cover) to verify
that you have the proper model.
The gas-supply pressure requirements in this table are for
reference only. (See the rating label for exact specifications).
GAS-SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Minimum Manifold
Pressure
Min. Gas-Supply
Pressure**
Natural Gas 5-in. Water Column 6-in. Water Column
Liquid Propane (LP) 10-in. Water Column 11-in. Water Column
*Gas-supply pressure for testing the regulator setting shall be at least 1 in. water
column (249 Pa) above the specified manifold pressure; **Max. gas-supply pressure
for all models: 1/2 psi.
The regulator is factory-installed. Use only the installed regulator.
The regulator inlet receives a 3/4” gas line. The range ships with
a 1/2”-to-3/4” adapter on the regulator.
Rating
Label