TRUE RESIDENTIAL
®
TEC_TM_009 Rev. B
December 31, 2019 Page 8 of 50
ELECTRICAL REQUIREMENTS
TR-30/TR-36
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A
dedicated circuit, supplying only this appliance is
required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
person in order to avoid a hazard.
• POWER SUPPLY 115 V AC, 60 HZ
• CIRCUIT BREAKER 15 AMP
• RECEPTACLE 3-PRONG GROUNDING-TYPE
NOTES:
THE OUTLET MUST BE CHECKED BY A
QUALIFIED ELECTRICIAN TO BE SURE THAT
IT IS WIRED WITH THE CORRECT POLARITY.
VERIFY THAT THE OUTLET IS PROPERLY
GROUNDED.
TR-30/TR-36 – FRONT VIEW
ROUGH OPENING &
ELECTRICAL AREA
84"
(2134 mm)
PROUD
INSTALL
84
1
/
4
"
(2140 mm)
FLUSH
INSTALL
77"
(1956 mm)
2"
(51 mm)
8"
(204 mm)
Electrical located
in this area.
30
1
/
4
"
(769 mm)
29
3
/
4
"
(756 mm)
FLUSH
INSTALL
PROUD
INSTALL
ANTI-SWEAT FOAM END PANELS
When installing two units side-by-side, it is recommended to leave a
5
8" gap between the cabinets, to ensure
that moisture does not develop. Anti-sweat foam end panels can be purchased from our parts department by
calling (844) 849-6226, or emailing trueresidentialparts@truemfg.com. If installing anti-sweat foam end panels,
we recommend that a panel be applied to each of the units being joined together.