Loading ...
Loading ...
Loading ...
English-54
How to connect your extended power cables
Items to prepare
(compressorandinsulationtapeshouldbepreparedbyaninstallationtechnician.)
1. As shown in the gure, peel o the shields from the rubber/wire
of the power cable.
- Peel o 20 mm of the wire shields of the tube installed already.
2. Insert both sides of core wire of the power cable into the connection sleeve.
3. Using a compressor, compress the two points and ip it over
and compress another two points in the same location.
- The compression dimension should be 8.0.
- After compressing it, pull both sides of the wire to
make sure it is rmly pressed.
4. Wrap it with the insulation tape twice or more and position your contraction
tube in the middle of the insulation tape.A total of three or more layers of
insulation is required.
5. Apply heat to the contraction tube to contract it.
6. After tube contraction work is completed, wrap it with the
insulation tape to nish.
Tools Crimping pliers
Connectionsleeve(mm)
Insulation tape
Contractiontube(mm)
Spec
MH-14 20xØ7.0(HxOD) Width18mm 50xØ8.0(LxOD)
Shape
40 mm
Insulation tape
Contraction tube
(Unit:mm)
120
60
202020
180
Powercable(providedbyus)
20
Wiretubepowercable
Connection sleeve
Comp. dim.
Compress it 4 times
5 mm
Insulation tape
• Incaseofextendingtheelectricwire,pleaseDONOTusearound-shapedpressingsocket.
- Incomplete wire connections can cause electric shock or a re.
• Forinformationaboutthepowercablespecicationsforindoorand
outdoor units, refer to the installation manual.
• Afterpeelingothetubewire,youmustinsertacontractiontube.
- Make sure that the connection parts are not exposed to outside.
- Be sure to use insulation tape and a contraction tube made of approved
reinforced insulating materials that have the same level of withstand voltage
with the power cable.(Comply with the local regulations on extensions.)
Loading ...
Loading ...
Loading ...