English-44
Evacuating the indoor unit
• TheremainingairintheRefrigerationcycle,whichcontainsmoisture,
may cause malfunction on the compressor.
• Alwayscontacttheservicecenteroraprofessionalinstallationagency
for product installation.
• Topreventdirtorforeignsubstancesfromgettingintothepipesduring
installation, do NOT remove the caps completely until you are ready to
connect the pipes.
The length of the pipe can be:
•Extendedupto:seetablepage35
•Shortenupto:seepage35
If you need a pipe longer than 5 meters:
• Youmustaddrefrigeranttothepipes;otherwise,theindoorunitmayfreeze.
Cutting or extending the pipe
1. Unscrew the caps at the end of each pipe.
Allinertgasexhaustsfromtheindoorunit.
Theindoorunitissuppliedwithinertgas(nitrogen).
Before installing the unit, check if nitrogen gas ow out of indoor unit.
Ifthisoneisn’ttrue,DONOTINSTALLTHEUNITsinceleakagecouldbeinsidetheindoorunit.
1. Make sure that you have all the required tools (pipe cutter, reamer, aring tool and pipe holder).
2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the
pipe (see below examples of correct and incorrect cut edges).
3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.
Oblique Rough Burr
Pipe
cutter
Pipe
• Facethepipedownwhileremovingtheburrstomakesurethatburrsdonotgetintothepipe.
Unscrew the capsPipes