ยค Factory setting : Natural gas = G20-20 mbar/G25-25 mbar
X Gas setting possible according to installation Butane gas G30-29 mbar or Propane gas G 31-37 mbar
CHANGING THE GAS TYPE :
the calorific capacity and pressure of the gas vary according to the type of gas.
When changing the gas, the technician should successively : change the jets, make
the gas connection to the installation and set the minimum flow of all the gas
burner tap.
INSTALLATION: GAS
CHANGING THE JETS OF THE GAS BURNERS
Hob burner jets
To gain access to the jets :
. lift the hob lid,
. remove the top, grills, caps and heads of all burners,
. use a tube spanner (7) inside the burner,
. according to the information given in the table,
install jets suitable for the burner type and gas type supplied.
For reinstallation, fit the heads, burner and top grills.
Each jet is identified with a mark.
JET
Jet
kW
Jet
kW
Jet
kW
Jet
kW
G20 20 mbar
1,00
1,75
2,50
3,50
G20 25 mbar
1,20
2,00
2,80
4,00
G25 25 mbar 0,90 1,60 2,30 3,20
G30 29 mbar
1,00
1,75
2,50
3,50
G31 30 mbar
0,90
1,60
2,25
3,20
G31 37 mbar 1,00 1,75 2,50 3,50
50 66 80 94
76 101 118 144
ULTRA-RAPID
front right rear left front left rear right
BURNER
AUXILIARY SEMI-RAPID RAPID
CAT. PAYS G20/20 G20/25 G25/25 G30/29 G30/36 G31/30 G31/37 G350/1
3
II
2E+3+
FR, BE
XXX X
II
2H3+
CH, ES, GB, GR, IE, IT, PT
XXX
II
2H3B/P
CZ, AT, DK, FI, NO, SE
X
X
X
I
2E
DE
X
II
2H3B/P
HU
X
X
X
II
2L3B/P
NL
X
X
X
II
2ELs3B/P
PL
X
X
X
GAZ/Pression (mbar)