Chef 540 Upright Cooker 9
Wiring connection for gas cooker
To allow for disconnection of the appliance after installation,
the plug must be accessible after installation, or a functional switch
must be provided near the appliance in an accessible position.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Gas connection
Read these points before connecting to the gas supply:
The cooker inlet connection point has a ½” BSP external
thread. See Diagram below
A NG regulator or a LPG test point fitting is supplied
It is recommended to fit the regulator or test point fitting to
the appliance connection point, then fit either hard piping
or a high level flexible connection (AS/NZS 5601.1)
which is then attached to the consumer hard piping
Ensure installation allows withdrawal of appliance.
Operation on universal LPG/propane
1. The appliance inlet fitting provided MUST be orientated
so that the pressure nipple is accessible.
2. The inlet fitting has ½” BSP internal thread at the inlet
and outlet.
Restraining Device
Anchor Points
Gas
Connection Point
150mm
650mm
installation
Checking pipe size
To work out a suitable pipe size for connection use the information in this table.
Gas Consumption (MJ/h)
Model Natural gas Universal LPG Propane
CFG503 58.1 45.7 56.5
CFG504 47 36.7 47.5
CFG513 60.2 48.2 58.3
CFG516 37.3 30.2 -
CFG517 49.1 39.2 49.3
CFG505 47 36.7 47.5
Use AS/NZS 5601 to ensure adequate
gas supply
Operation on NG
The appliance regulator MUST be orientated so that the
pressure nipple is accessible
The arrow showing the direction of flow MUST be
pointed correctly
The regulator has a ½” BSP internal thread at the inlet and outlet.
Restraining Device
Anchor Points
Connection
Gas
Point
150mm
650m m
Grill shutter
(Default shutter for NG use)
1/2”B SP
Internal Thread
Pressure test point
NG Regulator