TECHNICAL DATA:
MODEL
Airflex15 V2
Capacity
Cooling: 4000 W
Heating: 3200 W
Rated Input (EN 60335)
Cooling: 1538 W
Heating: 1391 W
Running Current
Cooling: 7.0 A
Heating: 6.3 A
Max Noise Level (Sound Pressure)
≤65 dB(A)
Air Flow
450 m3/hr
Maximum Allowable Pressure
3.2/1.0 Mpa
Permitted Excessive Operating Pressure
2.6/1.0 MPa
Power Supply
220-240V/50Hz
Refrigerant
R290/235g
Net Weight
28 Kgs
Gross Weight
32 Kgs
Dimensions (L*D*H)
321x580x767 mm
Unit must be vented outside when in Air Cooling and Heating mode.
For the purposes of EU regulation EN12102 this is a local air conditioner and