(7) to (9) FUNCTION INDICATORS
An LED will illuminate to show which mode the unit is currently in. This can be changed
between Dehumidify (7), Cooling (8) and Heating (9) using the Function Button (3)
(10) IR REMOTE SENSOR
Receives infra red signals from the supplied remote control
(11) to (14) FAN SPEED INDICATORS
An LED will illuminate to show which fan speed the unit is currently set to. This can be
changed between High (11), Medium (12), Auto (13) and Low(14) using the fan speed
button (6).
(15) LED DISPLAY
Shows the set temperature or timer settings while in normal operation. When the set
temperature or the timer is adjusted, the new setting is shown on the display.
When the TEMP+ or TEMP- buttons are pressed, the display will show the desired
temperature currently set.
When the [TIMER] button is pressed the number of hours remaining will be shown until
function is achieved or deactivated.
In the dehumidification function, “dH” or “CO” will be shown in the display (dependant on
model).
The LED display is also used to show error codes should a fault occur
E1
The room temperature sensor is open or of short
circuit.
E4
Water is full, need manual drainage
MULTI PROTECTIVE FUNCTION
ANTI-FREEZE PROTECTION CONTROL:
When the ambient temperature is low while in Cooling Mode, the compressor and water
pump will stop working if the copper coil temperature is too low. When the copper coil
temperature increases, the protection will be stopped automatically. While in this mode “Df”
will be displayed on the unit.
WATER-FULL PROTECTION:
When the water level in the internal water tank is above the maximum level, the unit will
alert automatically and E4 will be displayed on the LED screen. Please discharge the water
from the water tank by following the instructions in the “Water Drainage” section.
COMPRESSOR PROTECTION
The compressor has overheat protection which may stop the compressor to prevent
damage. The compressor also has a 3 minute delay protection function which delays the
start of the compressor, to help protect the compressor against repeated loss of power.