DUAL DUCTING THE UNIT
The Airflex 15 also supports dual ducting in both cooling and heating modes. This means
the unit can operate with two hoses connected at the same time.
To do this the unit should be set up with the Comfort Kit or a compatible gravity flap for
sending cooled / heated air into the room, with a second pipe connected sending the waste
air outside. I.e. in the winter the unit could duct the hot air into the room while ducting cold air
outside, with the unit inside to increase performance.
This is perfect for classroom environments or similar, where during summer the unit can be
kept in a store room, ducting cold air into the classroom, while ducting the hot air outside.
This both minimises the noise in the classroom, and keeps the unit safe from tampering.
To set up the unit for dual ducting, a compatible twin duct adaptor and a second 150mm
diameter pipe should be purchased from the original retailer or manufacturer. Details can
be found below: