Step 4-1: Installing an In-hood 600 CFM Blower. Duct connection detail: 6” round
Recommended duct size: 6” 8”
Figure A:
Set Discharge Direction,
Attach Blower
Unscrew blower plate and
set to top or rear discharge if
not already set correctly.
Screw blower to plate with
included hardware
Figure B:
Connect Plate Internally
Re-install all mounting
screws inside of liner.
Figure C:
Connect Plate Externally
Re-install all mounting
screws outside of liner.
Figure D:
Connect Power Supply
Plug 6-pin connector from
one of the control harnesses
to blower. Unused harness
may be tied securely to
other harness to prevent
vibration
Step 4-2: Installing an In-hood 1200 CFM Blower kit. Duct connection detail: 10” round
Required duct size: 10”
INSTALLATION INSTRUCTIONS
Figure A:
Set Discharge Direction.
If not already set correctly,
remove fasteners for top/rear
bracket and rotate to set to
top or rear discharge.
Reinstall all fasteners.
Figure B:
Remove Inner Plates
Remove all screws
securing blower mounting
plates and pull plates from
liner.
Figure C:
Connect Blowers
Install dual 600 CFM
blowers onto mounting
plates with included
hardware.
Figure D:
Install Blowers in Hood
and Connect to Power.
Reinstall blowers and
mounting plates to liner.
Plug 6-pin connectors from
control harness to each
blower.
9