Westinghouse Outdoor Power Equipment, LLC | 15
OPERATION
BEFORE STARTING THE GENERATOR
Verify that:
The generator is placed in an safe, appropriate location.
The generator is on a dry, at, and level surface.
The engine is lled with oil.
All loads are disconnected.
Fire and explosion hazard. DO NOT move or tip the
generator during operation.
STARTING THE ENGINE
1. Verify that fuel is in the gas tank.
2. Turn the fuel selector switch on the control panel to
gasoline operation.
3. Turn the fuel tank valve to the ON position.
ON
OFF
4. Push the battery switch to the ON position.
5. Choose the starting method:
a. Remote Start: Push and hold the START button on
the remote start key fob for one second.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
c. Recoil Start: Manually close the choke if the engine
is cold. Firmly grasp and pull the recoil handle slowly
until you feel increased resistance, then pull rapidly.
d. Cold start: Close the choke by moving it right
toward the front handle of the generator.
STOPPING THE ENGINE
1. Turn off and unplug all connected electrical loads.
IMPORTANT: Never start or stop the generator with
electrical devices connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3. Push and hold the START/STOP button for one second
or push STOP on the remote start key fob for one
second.
Note: Alternately, if the generator is used infrequently, turn
the fuel tank valve to the OFF position to limit the
residual fuel remaining in the carburetor oat bowl.
The engine will stop when fuel in the carburetor and
fuel line is exhausted.
4. Push the battery switch to the OFF position.
FREQUENCY OF USE
If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.
AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if
there is a short circuit or a signicant overload of the
generator at each receptacle. The main circuit breaker
will automatically switch OFF if the combined load of the
receptacles exceeds 40 Amps.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
Tripped
Operating
Push to Reset
ON
OFF
Receptacle Circuit Breakers Main Circuit Breaker