AMC / TDS OPERATOR’S MANUAL
9
Watermaze AMC/TDS Operator's Manual 8.913-965.0 - A
Electrical
Refer to Wiring Diagram
1. Run power for the AMC-2000 from the power inlet
terminal block of the Delta. (Wire not supplied.)
2. Run fi lter pump wires from AMC-2000 to the fi lter
pump motor. Wire the same way it is wired from
main control box. Install a tee at the motor to ac-
cept the line from the AMC. On a three-phase unit,
make sure fi lter pump is spinning in the correct
rotation from both power sources. (Wire not sup-
plied.)
3. Run the black N/O fl oat from the AMC to the fi lter
pump tank. Tie wrap N/O fl oat to existing low water
fl oat in fi lter pump tank.
Air
1. Air is required to operate air valves. 3 CFM with 60-
100 psi will meet air requirements.
2. An air regulator valve is provided.
3. Connect air hose to auto dump valve.