Karcher Alpha-1500D Above-Ground Separator 11034010

User Manual - Page 25

For 11034010.

PDF File Manual, 37 pages, Read Online | Download pdf file

11034010 photo
Loading ...
Loading ...
Loading ...
AMC / TDS OPERATOR’S MANUAL
25
Watermaze AMC/TDS Operator's Manual 8.913-965.0 - A
Step 16. Remove plumbing from return line off of the
carbon fi lter diverter valve to return line. Plug
both ends. Remove plumbing from carbon fi lter
diverter valve going to storage tank #2.
Step 17. Attach half union to remaining union (item 2)
on outlet from carbon fi lter. Glue elbow (item 4)
to union diverter valve as shown. Measure, cut
and glue 1-1/2" gray hose (item 3) to carbon
outlet port on AMC-3000.
AMC-3000
INSTALLATION INSTRUCTIONS (CONTINUED)
1-1/2"
Gray
Hose
Storage
Tank #2
Return
Line
Storage
Tank #2
Carbon Filter
Diverter Valve
Carbon
Filter
AMC-3000 Carbon Filter Outlet
Carbon
Filter
1
5
2
2
4
6
4
3
6
ITEM PART NO. DESCRIPTION
1 8.706-394.0 Plug, 1-1/2", PVC 80
2 8.706-470.0 Union, 1-1/2" Slip x Thread,
PVC 80 Spears
3 8.711-813.0 Hose, 1-1/2", Gray Spiralite, 50 ft.
ITEM PART NO. DESCRIPTION
4 8.706-374.0 Elbow, 1-1/2" S x S, PVC 80, 90°
5 8.706-424.0 Nipple, 1.5" x Close, PVC 80
6 8.706-367.0 Pipe, 1.5", PVC 80, 3 ft.
1
Loading ...
Loading ...
Loading ...