AMC / TDS OPERATOR’S MANUAL
Watermaze AMC/TDS Operator's Manual 8.913-965.0 - A
RUNNING PROGRAMS
Auto Backwash (Program A) - Used for
Daily Operations
1. Set program switch to Program A.
2. Turn control dial to AUTO/ON position. Program will
cycle through modes 1-4 when start time is reached.
Mode number and program letter will fl ash to indi-
cate status. Display will show time remaining in that
mode.
3. AMC-2000/3000 will return to fi lter mode when mode
4 is complete.
Manual Backwash (Program B)
1. Set program switch to Program B.
2. Turn control dial to AUTO/ON position.
3. Press the MANUAL START button twice. CLP will
cycle through the following modes:
• Media Backwash
Tank 1 Recovery
• Carbon Backwash
4. To skip a mode, press the NEXT button.
5. To pause a mode, press +/ON and -/OFF buttons at
the same time. To resume, press the NEXT button.
6. To cancel program press +/ON and -/OFF buttons
at the same time, twice.
7. Set program switch back to Program A to resume
Auto Backwash program.
Test Program (Program C)
1. Set program switch to Program C.
2. Turn control dial to AUTO/ON position.
3. Press the MANUAL START button.
4. See Running Manual Backwash instructions above
to pause, skip and cancel programs.
5. Set program switch back to Program A to resume.
OPERATION: AMC-1000
During normal operation, the settling properties of solids
will result in sludge build-up inside the cone bottom of the
clarifi er tank. This sludge must be periodically removed.
The AMC-1000 automated sludge dump system is de-
signed to remove solids each day.
To dump sludge from the cone bottom tank, a 24-hour
timer in the AMC-1000 control box energizes an air
activated dump valve (ASV5). The duration of the dump
mode can be adjusted by a second timer (measured in
seconds). Once the dump valve closes, the sludge bag
is allowed to de-water and excess water is returned, via
gravity feed, to the wash pad catch basin.
OPERATION: TDS-1000
The TDS-1000 dramatically reduces the Total Dissolved
Solids (TDS), Total Suspended Solids (TSS) and even
detergents that can accumulate in a recycle system. The
TDS-1000 is designed to remove a specifi ed volume of
water from the system each day. The freshwater make-
up system on the CLP or Delta will then add fresh water
to the system.
To purge water from the CLP or Delta system, a 24-hour
timer in the TDS-1000 control box energizes the rain
water solenoid found on the water connection panel.
The transfer pump will turn on and discharge water from
tank #2 to a holding tank or to sewer (if permitted). The
duration of the dump mode and therefore the amount of
water purged can be adjusted by a second timer. The
freshwater solenoid on the water connection panel is
disabled while the system purges. A N/C fl oat is supplied
with the TDS-1000 to prevent overfl owing the water in
the holding tank.
INSTALLATION
INSTRUCTIONS:
AMC-2000
NOTE: Different models and years of manufactur-
ing may have been built slightly different from the
instructions below. It is recommended you have a va-
riety of fi ttings available for those slight differences.
Tools & Supplies
• 1" Hole Saw
• Large Channel Locks
• Medium Straight Screw Driver
• Small Straight Thin Screw Driver
• Hack Saw - Don't Use Pipe Cutter
Tape Measure
• Drill
Tefl on Tape
• Purple Primer
• Heavy Duty Gray PVC Cement
• Rags
Wire/Conduit — depends upon amp draw of
machine and fi lter pump. Follow local codes.
Electrical fi ttings (Spader, butt connector, etc.)
Wire Strippers
Wire Cutters