20
AMC / TDS OPERATOR’S MANUAL
Watermaze AMC/TDS Operator's Manual 8.913-965.0 - A
Step 3. Break pipe union coming off of multi-media tank
diverter valve that goes to return line. Follow
this line down to return line and break that union
or unions. Remove pipe. (On some models you
may also have to break unions on carbon fi lter
to remove this pipe.
Step 4. Remove remaining elbow and adapter from
multi-media valve head. Install 1-1/2" plug (item
1) into valve head port.
Step 5. Take threaded half of slip x thread 1-1/2" union
(item 2) and couple to remaining half union
coming off return line. If existing union on return
line is different from one supplied, cut old union
off and install new union. Thread in 1-1/2" pipe
(item 1) plug into this union. (Depending on
model and when it was built you may not need
to do this. What you need is one line open going
to the return line. Most CLP machines have two
- so on those units you will need to plug one.)
Storage Tank #1
Multi-Media Tank
Diverter Valve
Storage
Tank #2
Multi-Media
Filter
Return Line
1
Multi-Media
Valve Head Port
Storage Tank #1
Storage
Tank #2
Return
Line
AMC-3000
INSTALLATION INSTRUCTIONS (CONTINUED)
2
1
ITEM PART NO. DESCRIPTION
1 8.706-394.0 Plug, 1-1/2", PVC 80
2 8.706-470.0 Union, 1-1/2" Slip x Thread,
PVC 80 Spears
3
3
4
4
5
5