Loading ...
Loading ...
Loading ...
33 33-00478–04
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and
easily.
Display is blank
Check circuit breaker and reset if necessary.
Make sure power switch for heating and cooling is on.
Make sure furnace door is closed securely.
Make sure the C-wire is connected.
Make sure R/Rc slider tab is set correctly (see wiring diagrams).
Heating or cooling system does not respond
Press Menu > System Mode > Heat > Done to set the system to Heat mode. Make sure the desired temperature is higher
than the indoor temperature.
Press Menu > System Mode > Cool > Done to set the system to Cool mode. Make sure the desired temperature is lower than
the indoor temperature.
Check circuit breaker and reset if necessary.
Make sure power switch for heating and cooling system is on.
Make sure furnace door is closed securely.
Wait 5 minutes for the system to respond.
Temperature settings do not change
Make sure desired temperature is within acceptable ranges:
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
Aux heat runs in cooling
For heat pump systems, verify there is not a wire attached to W on the UWP.
Cool runs with a call for heat
For heat pump systems, verify there is not a wire attached to W on the UWP.
Sensor will not connect
Press and hold Connect on the wireless sensor for 15 seconds. The LED will turn Amber. Return to the thermotat menu and
press Menu > Devices and Sensors. Follow the on-screen instructions to add the sensor.
Loading ...
Loading ...
Loading ...