7
Permitted natural gas connections itemised according to
countries:
Liquid gas connection (LPG)
Caution!
Follow country-specific guidelines.
If liquid gas (LPG) is used, the gas connection is established
via a gas hose or a fixed connection.
If a gas hose is used, pay attention to the following measures:
Use a safety hose or plastic hose (8 mm diameter).
Secure it to the gas connection with a connecting device (e.g.
a hose clamp).
The hose must be short and fully leakproof. The hose must
not be longer than 1.5 m. Pay attention to current guidelines.
The gas hose must be replaced annually.
Insert the safety hose and tighten using a screw coupling or
hose clamp.
Carry out a leak test once connection is complete. See the
section entitled "Leak test".
Conversion to a different gas type
Measures to note
The appliance may only be converted to a different gas type
by an approved specialist, in accordance with the
instructions in this manual.
Incorrect connection and incorrect settings may cause
serious damage to the appliance. The appliance
manufacturer accepts no liability for damage and
malfunctions of this kind.
Pay close attention to the symbols indicated on the rating plate.
If there is no symbol for your country, follow the technical
guidelines that apply in your country when making settings.
Before setting up the appliance, determine the gas type and
pressure in the local supply network. Before using the
appliance for the first time, make sure that all settings have
been made correctly.
Pay attention to local and international rules and regulations.
All connection data can be found on the rating plate on the rear
of the appliance at the bottom.
Enter the data in the following table:
Product number (E no.),
Manufacturing number (FD),
Enter the factory settings for gas type/gas pressure, as well as
the settings for gas type/pressure that apply after the gas
conversion, in the following table.
The changes made to the appliance and the type of connection
play an important role in ensuring that the appliance operates
correctly and safely.
Country
EN 10226 R
^
(TS 61-210 EN
10226 R
^)
EN ISO 228
G
^
(TS EN ISO
228 G
^)
AT Austria X
BE Belgium X
CH Switzerland X
DE Germany X
ES Spain X X
FR France X
GR Greece X
IT Italy X X
NL Netherlands/Holland X
PT Portugal X X
HR Croatia X
SL Slovenia X
YU Serbia X
TR Turkey X X
PL Poland X X
RO Romania X X
AE United Arab Emirates X
ZA South Africa X
HU Hungary X
RU Russia X
GB United Kingdom X
/3***
E no. FD no.
After-sales service
O
Type of gas / gas pressure
Data on the rating plate
Type of gas / gas pressure
Data after gas conversion