Loading ...
Loading ...
Loading ...
11
INSTALLATION INSTRUCTIONS
Leak-testing and flame-testing the cooktop
IMPORTANT!
The operation of the cooktop, including the ignition system, must be tested before
installation is complete. If, after following the instructions below, satisfactory
performance cannot be obtained, contact the local gas authority or your local
Authorised Repairer for advice and assistance.
Checking the connections for leaks
After installation and making all connections, check thoroughly for possible leaks and
make sure all connections are gas-tight.
1 Turn all control dials to O (OFF).
2 Open the valve on the gas supply.
3 Check each connection one at a time by brushing a soap and water solution or a
suitable leak detection fluid over it.
IMPORTANT!
Do not use any naked flames to check for leaks.
The presence of bubbles indicates a leak. Tighten or replace connections as
appropriate, then leak-test all connections again. Ensure the fibre washer (supplied) is
located between the elbow and the cooktop’s gas inlet.
Checkng the burner flames
1 Light each burner.
2 Check for a well-defined blue flame without any yellow tipping.
If any abnormality is evident, check that:
the burner cap is located properly
the injector nipple is correctly aligned
the correct size injectors are installed.
Incorrect: flame
‘lifting off’ the burner
Incorrect:
yellow tipping
Good flame: well-defined blue
flame without yellow tipping
Incorrect and good flame patterns
Loading ...
Loading ...
Loading ...