INSTALLATION INSTRUCTIONS
Gas connection with a flexible hose
If the gas is connected with a flexible hose, the connector on the wall should be
between 800-850mm above the floor and to a distance of at least 250mm outside the
width of the cooktop. The connector should be accessible with the cooktop installed.
Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certified. The
thread connection shall be Rp ½” (ISO 7-1) female.
The hose assembly must be as short as practicable and comply with relevant AS 5601/
NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces (eg base of metal
hotplate, flue or chassis of underbench oven etc).
Fibre washer
Elbow (1/2” BSP external thread)
Gas connection to the cooktop