IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
REPLACINGCOMPONENTS
ControlBoard
TheControlBoard(Part#PAH‐CB09)isadigitalread‐outboard.Thisboardoffersawide
varietyofsettingstooperatetheunit.Therightsidepanelshouldberemovedpriortoremovingthe
controlboard,usinga
5
/
16
”wrenchornutdriver.Thecontrolboardcanberemovedfromtheunitby
looseningthetwooutsidescrewsandpullingtheboardbacktotheinsideofthestove.A6‐amp
“quick‐blow”fuseisusedonthisControlBoard.
NOTE: Thebottomthreecontrolbuttonsarepresetatthefactoryandarenotuseradjustable.See
the “Daily Operation” section on page 18 of the manual for more instructions on Control
Boardsettings.
RecommendedHeatRanges:
LowBurn: HeatRangesetting:1 RoomAirBlo wer setting:1
MediumLow: HeatRangesetting:2–3 RoomAirBlowersetting:*
MediumHigh: HeatRangesetting:4–8 RoomAirBlowersetting:*
HighBurn: HeatRangesetting:9 RoomAirBlowersetting:9
*NOTE:BlowerSpee d willautomaticallybeadjustedtothedesiredHeatRangethatyouselect.