29
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
YEARLYMAINTENANCE
ExhaustBlowerCleaning
Althoughtheexhaustblowerandblowerhousing
weredesignedtominimizeashbuildup,someflyashwill
stillaccumulatetherethroughouttheburningseason.
Theamountandtypeofashwilldependonthetypeof
pelletsandventingsystem,butgenerallythis
accumulationwillbemild.If,whencleaningtheexhaust
blower,alargeaccumulationofflyashisfound,cleaning
theexhaustblowerandhousingshouldbeperformed
monthlyorbimonthlytopreventthisexcessbuildup.
Instructions
Beforebeginningtheexhaustblowercleaningprocedure,becertaintheunitisunpluggedand
thoroughlycooleddown.
Removetheleftsidepanelofthestove,usinga5/16”wrenchornutdriver.
Disconnecttheventingsystemfromtheexhaustblowerjustenoughthatyouwillbeabletoremove
theexhaustblowerfromthestove.
Oncethepanelisoff,theexhaustblowerwillbeclearlyvisible.
Unplugthetwowireswhichconnectthestovewiringharnesstotheexhaustblower,usingthequick
connectplugs.Disconnecttheheatsensorthatismounted(withascrew)totheexhaustblower.
Loosenthefive(5)
5
/
16
selfdrillingscrewswhichholdtheexhaustblowertotheexhaustblowertube.
Lifttheexhaustblowerupandoutofthestove.Thegasketwhichsealstheexhaustblowertothe
exhaustblowertubeisfragile,sotakeextracarewhenremovingtheblower.Evenwhenbeingcareful,
though,itiseasytotearthisfragilegasket,andsinceanairtightsealiscrucialhere,itisbesttoreplace
thisgasket(Part#‐PUCBMG)everytimetheexhaustblowerisremoved.
Withtheexhaustblowerremoved,useautilityvacuumtoremoveanyashaccumulationintheexhaust
blowertube.
Useasoftpaintbrushandcarefullyremoveanyashaccumulationfromtheinsideoftheexhaust
blower,andfromtheexhaustblowerfanblade.
Inspecttheexhaustblowermotorfordustaccumulationandcarefullyremoveit,ensuringthatallair
coolingholesintothemotorareopenandfreeofdustdeposits.
Installtheblowerinthereverseorderasdescribedabove.Remembertochecktheconditionofthe
exhaustblowergasketandtoreplacetheheatsensorontotheexhaustblower.
Reinstalltheventingsystemandpanels.
ConvectionBlowerCleaning
Asalways,becertainthestoveiscoolandunpluggedbeforeservicinganycomponentswithintheunit.
Sincetheconvectionblowerdoesnothandleanybyproductsofcombustion,itdoesnotrequireserious
cleaningliketheexhaustblower.However,dustfromthehomeandotherdebrisintheaircanaccumulateon
thebladesoftheconvectionblower.Removetherearpaneloftheunit,usinga5/16”wrenchornutdriver.
Theconvectionblowerislocatedinthemiddleofthestove(seeimage,above).Anydustthathasbuiltupon