36
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
REPLACINGCOMPONENTS
VacuumSwitch
Beforebeginninganycomponentreplacement,becertaintheunitisunpluggedand
thoroughlycooleddown.
Removetherightsidepanel(seepg.43forpanelinstructions).Removaloftherearpanel
mayhelp,aswell.
Locatethevacuumswitchasshowninthediagrambelow.
Disconnectthe
stovewiringharnessandvacuumhosefromthevacuumswitch,takingnote
ofwhereconnectionsweremade.
Removethe(2)screwswhichholdthevacuumswitchtothevacuumswitchbracket,using
aPhillipsscrewdriver.
Installationisthereverseofremoval;beabsolutelycertainthewiresand
vacuumhoseare
connectedastheypreviouslywere(andaccordingtothewiringdiagraminthismanual).