Installation
63
EN
Nozzles not provided are available at Authorised Service Centres
8 Natural gas G2.350 – 13 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.0 2.4 1.0 3.8
Nozzle diameter (1/100 mm)
94 148 100 200
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
YF30H3
9 LPG G30/31 - 30/37 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 0.9 4.0
Nozzle diameter (1/100 mm)
50 79 48 98
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
-Z- -
Rated flow rate G30 (g/h)
76 182 65 291
Rated flow rate G31 (g/h)
75 179 64 286
10 LPG G30/G31 - 37 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.1 2.5 0.9 4.1
Nozzle diameter (1/100 mm)
50 75 48 94
Reduced flow rate (W)
450 800 450 1600
Pre-chamber (printed on nozzle)
-Z- -
Rated flow rate G30 (g/h)
80 182 65 298
Rated flow rate G31 (g/h)
79 179 64 293
11 LPG G30/G31 - 50 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.0 4.0
Nozzle diameter (1/100 mm)
43 65 43 75
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
H2 H8 H2 S1
Rated flow rate G30 (g/h)
76 182 73 291
Rated flow rate G31 (g/h)
75 179 71 286
12 Town gas G110 – 8 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.7
Nozzle diameter (1/100 mm)
145 230 140 320
Reduced flow rate (W)
400 800 400 1400
Pre-chamber (printed on nozzle)
/8 /3 - -
13 Town gas G120 – 8 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.8
Nozzle diameter (1/100 mm)
135 220 130 300
Reduced flow rate (W)
400 800 400 1400
Pre-chamber (printed on nozzle)
/8 /3 - -