Installation
60
Adjusting the minimum setting for natural
or town gas
1. Light the burner and turn it to the minimum
position.
2. Remove the knobs by pulling them
upwards.
3. Turn the adjustment screw on the side of
the valve stem until a steady minimum
flame is obtained.
4. Refit the knob and verify that the burner
flame is stable.
5. Turn the knob rapidly from the maximum
to the minimum setting: The flame should
not go out. Repeat the operation for all
gas cocks
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve stem clockwise all the way.
Lubricating the gas cocks
Over time the gas cocks may become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
Lubrication of the gas cocks should
be performed by a specialised
technician.