Installation
59
EN
5.5 Adaptation to different types of gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
cocks.
Replacing the nozzles
1. Remove the pan support grids from the
hob.
2. Remove the flame-spreader crowns and
relative burner caps.
3. Unscrew the burner nozzles using a 7 mm
socket wrench and replace them
according to the type of gas to be used
(see the “Burner and nozzle
characteristics table”).
4. Replace the burners in their respective
housings.
The nozzle tightening torque must
be no more than 3 Nm.