Burner and nozzle characteristics table
1 Natural Gas G20 – 20 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.9
Nozzle diameter (1/100 mm)
72 108 80 145
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
X Y H1 H4
2 Natural Gas G20 – 25 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.9
Nozzle diameter (1/100 mm)
72 103 75 135
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
X Y H1 H4
3 Natural Gas G25 – 25 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.9
Nozzle diameter (1/100 mm)
72 115 80 150
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
F1 F3 H1 H4
4 Natural gas G25.3 - 25 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.9
Nozzle diameter (1/100 mm)
72 115 80 150
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
F1 F3 H1 H4
5 Natural gas G25.1 – 25 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.0 4.0
Nozzle diameter (1/100 mm)
77 115 80 155
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
F1 F3 H1 H4
6 Natural Gas G25 – 20 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.5 1.1 3.9
Nozzle diameter (1/100 mm)
77 124 85 155
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
F1 F3 H1 H4
7 Natural Gas G27 – 20 mbar AUX RR UR2 Int. UR2 Ext.
Rated heating capacity (kW)
1.05 2.4 1.0 3.9
Nozzle diameter (1/100 mm)
77 124 85 160
Reduced flow rate (W)
400 800 400 1600
Pre-chamber (printed on nozzle)
F1 F3 H1 H4